Fanuc parameter 1815 bit 3. The two Spindle Amps are A06B-6088(M) and A06B-6078(S).
Fanuc parameter 1815 bit 3 When it does that I bring it around to T1 and set the home position in parameter 1815 bit 4. (When a distance coded linear scale use, set "1". 08-16-2011, 11:22 PM Input of CNC Parameters 1. x. 4176 to 4283) 4176 Bit Bit parameter 4177 Bit Bit parameter 4178 Bit Bit parameter 417 ; Page 1324. Die X – Achse aus zu spindeln ist kein Thema, welches Bit ist es ? APZ für die X – Achse ? Wo setze ich den Bezugspunkt in der Z – Achse? Welches Bit? Aug 13, 2014 · Fanuc 21i-T Parameters Takisawa E-110 Turn 1815. (Parameter can be changed in MDI mode or emergency stop status. Cycled power and got all three axis zero return required alarm. Parameters will be input. Was able this time to change bit four to one. If you changed this parameter from a 0 to 1 then maybe you didnt do the procedure correctly. parameter 1815 to meet APC value put 1 if 0 3. 2 After setting any of these parameters, turn the power off then on again so that the setting will take effect. DESCRIPTION OF PARAMETERS B-63530EN/03 1 Set bit 1 (OPTx) of parameter No. Gruß Holger Aug 13, 2008 · 1 These parameters can be used also in a system that uses the Inductosyn. Its for the z axis just change the x insted of the z . fanuc synchronous built-in servo motor dis series parameter manual b-65270en fanuc ac spindle motor αi- b / βi-b series descriptions -65452 en fanuc ac spindle motor αi/βi series, built -in spindle motor b i series parameter manual b-65280en fanuc servo amplifier αi– b series descriptions b -65412 en Oct 1, 2017 · To clear your APZ alarms, set parameter 1815, bit 4 (which is the APZx bit) to zero for all axes (there will be one line for each axis your machine has). When input is complete, power the CNC OFF and ON. alarm went away and i could run in the spindle in. Problem: I lost my home position, still dont know how, from a shut down of two days this issue appear. Table below lists the manuals related to model a of May 29, 2010 · 2: change pare #1815 bit 5 from 1 to 0, power off then on, change back bit 5 to 1. Here is the problem: This machine is fitted with absolute encoders. I'll have to dig up the directions on the X_____ input bits tomorrow at work Jun 17, 2015 · Fanuc. If an axis has this bit set to 1, then you would have to see a battery pack or a cable that goes to an external battery pack connected to the front of the amplifier at the battery connection on the front of the amplifier (the marking varies). Can somebody tell me which the parameter is that I need to change. Also wer kennt sich damit aus, bzw kennt diesen Maschinentyp und dessen eigenheiten. Dec 2, 2018 · Here is what you are doing: When the parameter 1815 APZ column changes to a zero, this means the absolute encoder in the respective axis has lost its zero position. Does this mean that you are not in E-STOP anymore? 1815 will have no effect on the machine "comming up". Alm 000 will apear to power off the control. I am in deep trouble since two weeks. Fanuc 20-FA Parameter Manual B-62180E/01. Arrow down to whichever axis you want to change X,Y,or Z. Apr 10, 2017 · went to diagnostics it sent me to 352 code 9053. Dec 16, 2011 · The APZ bit of parameter 1815 has gone to zero for all these axes. (Do not hold in any other keys or risk loosing parameters, programs and more) Once powered up fully perform Zero Fanuc controls only. This will delete the current reference zero. 1815 to 0/1 to enable an encoder with absolute addressing reference marks (linear scale/rotary encoder). DCLx As a separate position detector, the linear scale with reference absolute addressing mark (A/B phase) / the Linear scale Parameter 21 Bit 0 APCX, Bit 1 APCY, Bit 2 APCZ, Bit 3 APC4. To purchase a common parameter cheat sheet list go to the cnc store Commonly altered Fanuc parameters list. Perform homing, alarm 90 again SETTING α SERIES SERVO PARAMETERS B-65150E/04 (4) Setting parameters Linear type In addition to the conventional settings for a separate detector (bit 1 of parameter No. Power on the control pressing letter (P) and the cancel (CAN) key and keep them depressed until the CRT Display comes up plus an additional 5 seconds. Mar 6, 2025 · Today we are going to change the parameter that allows us to use local subroutines on your Fanuc control. Reference point setting Change PWE to 1 Confirm Parameter 1002 bit 1 = 1 Confirm Parameter 1815 bit 5 = 1 Change Parameter 1815 bit 4 to 0 Check parameter 1320 and 1321 and record the settings went to diagnostics it sent me to 352 code 9053. Bitte das nur machen wenn es nicht anders geht. PARAMETER BIT VALUE CHANGE; 1300: 1: 1: Turn off overtravel alarm when handle jogging Jun 21, 2012 · Try to change parm 1815 bit 4 to a one. May 18, 2006 · DMG/Mori is very helpful over the phone but no-one knows yet why the zero return = Valid/Invalid option under the customize screen does not show up. 1815 to 1, and bit 3 (DCRx) of parameter No. The machine hasta be live to set the 1815 params. 3- Turn parameter write on. if a 1, something is holding position. This disables the editing of program Nos. Jan 28, 2009 · Change "Parameter write enable" to a 1 Ignore the stupid alarm telling you you enabled parameter write Press "System" key Press "Parameter" soft key Type "1815" and press the "O-Sch" soft key Cursor over to the APZ bit on parameter 1815 for the axis you want to reset Nov 27, 2013 · 5) In the System -> Parameters area, find Parameter #1815. Parameter 22 Bit 0 ABS-X, Bit 1 ABS-Y, Bit 2 ABS-Z, Bit 3 ABS-4 Or Parameter 1850 Gridshift. It also provides details on the different formats used for parameter input and output. Data type For the subspindle when the spindle switch function is used (Nos. 1815 to 1, bit 2 (DCLx) of parameter No. ) grid shift adjustment . DESCRIPTION OF PARAMETERS B–63380EN/02 Table 1 These parameters can be used also in a system that uses the Inductosyn. What are the settings for the following parameters: 1300 1320 1321 1326 Dec 13, 2002 · Procedure for absolute encoders on Fanuc 15/18/21 (IIRC) MDI mode Press "Settings" hard key and "settings" soft key Change Parameter Write to (1) - Ignore the stupid alarm Press "System" hard key, Press "Param" soft key Type in 1815 and press 'Osrh" (search) soft key Cursor over to the bit "APZ" for the Z axis GE Fanuc Automation Computer Numerical Control Products Warnings, Cautions, and Notes as used in this publication. parameter 1815 APC and APZ used to reference all the axis . . 6- Go to the "position" page and select "relative" and hit "x" and set the origin. It explains how to display parameters from the control unit, set parameters from MDI, and transfer parameters to and from the control unit using the RS-232C interface. Anyway I reset it by using Parameter 1815. Feb 6, 2015 · Parameter 1815 APZ bit Check with your yellow Fanuc parameter manual. It tricks Jun 13, 2006 · Once you were there, you'd toggle the #1815 bit "APZ" and restart the control. absolutes Meßsystem und trotzdem Referenz anfahren, gerade weil das ja auch um ne 18er Steuerung geht, gehe ich mal davon aus das der Parameter 1815 Bit 4 und 5 gesetzt ist. Sample: Fanuc 3T Parameters; Parameters Fanuc 6M; Last edited by swealf; Turn 1815. f0 control: Nov 21, 2009 · 2. Here is the axis zero setting for a Fanuc oi mate. Fanuc 11m parameter write protect. power off, then ON and perform Y homing, alarm 90 again. The bit will (ironically enough) be labeled NE9. Recommended. Über Hilfe bin ich dankbar. turn off machine for 20 sec after each x or y axis giving values This document describes how to display, set, input, and output parameters for FANUC Series 0i-MODEL F Plus CNC systems. 3. But there is no such parameter. I should work for your machine. von dem geht ja bekanntlich alles andere aus aber das nur nebenbei May 23, 2009 · The 21T should be an absolute encoder machine. bit 4 back Feb 13, 2018 · The value of this parameter is in range from -99999 to 99999. Aug 13, 2008 · NOTE Using tentative absolute coordinate system setting requires setting bit 1 (OPTx) of parameter No. Turn the control power off. No. NOTE: After each change of parameter 1850 turn off the machine and re-start. parameter 1815 bit 4 is likely now set to zero on the axis that you fixed the servo. axis is on screen, but no any alarms. HELP!!!! Fanuc 21i lathe, grid shift Type 1815 and press "No. ) Subroutines Fanuc Parameter 6005. X, Y, Z axis in 1850 parameters are not 0. Diag param 202 indicated a 1 for PHA, which indication there is phase Feb 1, 2020 · Der Referenzpunkt der Achsen sollte ja im Parameter 1815 hinterlegt sein (auch wenn ich nicht weiß welches Bit der richtige ist). Oct 2, 2010 · hallo zusammen, hab ein problem mit meiner fräsmaschine bzw. The max parameter is 900 something. After I do that I power down the machine for a minute. You can not run the machine with these values. 9000 to 9999 is automatically set to 1. Werkzeugvermessung und Anholmaß wieder einstellen!!!!! Generell solltest du danach schauen lassen da irgendwas nicht stimmt. Search" . If your machine has a PC that is connected to the controller via HSSB or you use HSSB features of FANUC’s NCGUIDE simulation software the setup procedure is slightly different. Continue setting the APZ bits to zero for each remaining axis. when bit 1 (DLZ) of parameter No. Press (READ) and (EXEC) soft keys. 1 : A separate pulse coder is used. 1002 is set to 1 or bit 1 (DLZx) of parameter No. 3. Problem is that i can't get the "Z" axis APZ bit at parameter 1815 to toggle to a "1" If i have the APC bit already set to a "1" Aug 8, 2004 · When I went to set bits 4 and 5 of parameter 1815 to 1, I could only change bit 5. How to set zero return position for fanuc controls. But when the gear shift shaft becomes defective and the mechanical connection between the spindle and the spindle motor is interrupted. 1: A separate pulse coder is used. I'm sure I"m missing something. After you have changed the bit for the first axis, an alarm will come on that power must be turned off. When I power back up I get the EX208 again. I cant change parameter 1815 bit APC for turret axis (machine shown APC alarm) and when i change bit APZ from 0 to 1, after turning off the value become zero by itself. vor ein paar wochen wurde der APC alarm ausgelös d. z and pos. I've done the toggle #1815 bit "APZ" only method, but only on a rotary axis, where I was using an indicator and sweeping a fixture straight to define it's "home" position. Oh and before you get over excited this option is only on newer Parameter #7 #6 #5 #4 #3 #2 #1 #0 1815 DCRx DCLx OPTx [Data type] Bit axis OPTx Position detector 0: A separate pulse coder is not used. Once turned on again, jog turret to soft stop on pos. There are 2 (x12/4000Vis) motors and 1 (x22/4000HVis). Alarm must power down will appear, DO NOT POWER OFF Aug 5, 2012 · <noindex> gridshift </noindex> там есть такая строка: for machines using absolute pulse coders. Bit 4 stayed at zero. Parameter 1815 bit 4 With the description APZ Parameter 1815 bit 5 With the description APC Regards Phil. The two Spindle Amps are A06B-6088(M) and A06B-6078(S). Change these settings according to the unit you actually use. 3: move Y axis far from home position, change para #1815 bit 5 from 1 to 0, bit 4 from 0 to 1. You need to either look in the manual of call the machine mfg & manually move the machine to where zero should be. ) Page 1704. Parameters #7 #6 #5 #4 #3 #2 #1 #0 1815 DCRx DCLx OPTx Data type : Bit axis type OPTx Position detector 0 : A separate pulse coder is not used. Horizontale 2 Achs Maschine. 1874, and parameter No. Parameters required for output are as follows : In addition, indicates the standard setting for input/output devices made by FANUC. Fanuc controls only. Adjusting gridshift and 2nd Zero Reference return position for tool changer and pallet changer. 5 off. 1875. But I still get the 300 Alarm Feb 12, 2014 · 2. xxxxxx0x (x = don’t change) 1820 = 2 2084 = 1 2085 =100 2024 = 12500 These will only allow you to move for testing only. 4 of the TURRET SERVO line to 0, then 1. Jun 13, 2023 · Hi I have a Daewoo h63 machine tool with 18 Fanuc control system. when i tried to test the atc it stopped above the tool, then when i tried to run all 3 axis they all Backlash Parameters Please see Backlash parameters and backlash adjustment procedures. when i tried to test the atc it stopped above the tool, then when i tried to run all 3 axis they all I have a custom machine with 3 fanuc servos. -----Think Snow Eh Ox DESCRIPTION OF PARAMETERS Table 4. It doesn't use dogs to reference, the reference is a digital count value stored in the memory of the drive. DMG/Mori suggested that I call Fanuc to see why the pendant won't allow me to edit parameter 1815 bit 4 to "1" but Fanuc just refered me to Mori unless I signed up for a warrantee program with them. Hardplates Stainless. ) DCLx Separate pulse coder 0 : A distance coded linear scale is not Page 1704. 1815, bit 5 (APCx) of parameter No. Here is what you are doing: When the parameter 1815 APZ column changes to a zero, this means the absolute encoder in the respective axis has lost its zero position. -Arrow down to whichever axis you want to change X,Y,or Z. 9000 to 9999. die speicherbatterie war leer. I done accordingly but problem still persists. after rebuilding the spindle and reinstalling, i had to orientate the spindle using param 4077, after restarting alarm sv0417 ill dig servo parameters all 3 axis. power off----- power up---reset xyz to home manually as per instructions on screen all went fine machine and control work fine EXCEPT for tool changer t(x) mo6 will call up tool change program and will preform a tool change but will not rotate the carocell Fanuc 30i 31i 32i Parameter Manual. When you turn it I have a custom machine with 3 fanuc servos. - clear prm 1815 bit 5 for the axis you want to remove (to avoid APC alarms) - CNC off, remove cables from the table, remove table, CNC on Now the add. power off/on and your #1 turret position should be good. assuming your turret is servo driven your parameter 1815 will have lines for X, Z and 3 (or some other axis letter/number for the turret servo) all you have to do is put the turret to the physical position where tool #1 should be and toggle 1815. h. der steuerung GE Fanuc 0i MC. In this video detail explanation of how to set reference of CNC machine . SRH" soft key (number search) should bring you to Parameter 1815 Jan 4, 2014 · 3- Write down the value in parameter 1250 for x and z. Display to PARAMETER screen by pressing `{`SYSTEM`}` key and (PARAM) soft key. When the axis is necessary again, just set 12#7 (and 1815#5, if absolute pulsecoder is used), CNC off, connect cables, CNC on and you have additional axis Dec 1, 2023 · FIG 3: Fanuc 31i Model B Diagnosis data output (1) FIG 4: Fanuc 31i Model B Diagnosis data output (2) HSSB. Went back to parameter 1815. Then set the parameter to 1 & power off & on. Resetting a home position by flipping a Parameter 1815 bit is not a thing here. When you turn it back to a 1, this enables you to move the axis back to zero if it is not. Dec 21, 2019 · To turn the scales off you must change the following parameters: 1815 bit 1 to a 0. Power on/off. Set a proper value in parameter Dec 13, 2002 · This is the version of "Alpha" that can run either the Alpha language or straight "Fanuc G" code. Turret is indexing to the wrong number position. 5- Using your co-ax indicator jog x down and zero it in the x axis plane on one of the 3 boring tools that all read the same. als ich zum batteriewechseln gekommen bin waren die referenzpunkte schon verloren gegeangen. 3 Bit Format Mar 19, 2008 · ( on our own machines we have a parameter 1815 bit 4 which we make 1 to solve the problem. Jetzt aber Vorsicht da der Nullpunkt um diese 2-3 mm verstellt ist. Powered on/off. change paramater #1815 to 0 again and write protect on with the 0 value. fanuc alarm DS0300: APC Jan 16, 2010 · If you changed this parameter from a 0 to 1 then maybe you didnt do the procedure correctly. Hallo zusammen, bei einer Fanuc 18 T Steuerung wurden die Leistungsteile in X und Z von mir getauscht. My machine tool builder asked me change parameter 1815 for positional reference. SETTING α SERIES SERVO Jun 13, 2020 · Using parameter 1815 Nov 6, 2010 · Set 1815 ZRN to 1 PWE to 0 Cycle power You say that you have gone through the procedure several times. the machine will alarm, now you can change to 9000 programs just make sure you go back in and turn the parameter write disable back on so you don't change something else on accident or have some one else changing things. Power Off then On, change para 1320 limit 1+, set for Y axis value is 99999999. Turn off machine. Maschine aus/ein. I set it to 1, and I get the alarm to turn off the power, but it doesn't take the parameter change. Change bit 4 (APZ) (make sure you count from the right starting with first space is Zero, Bits are as shown here-76543210). If you have anything to add to this list please let me know May 20, 2011 · Go to the offset setting pages under settings there is a parameter write enable you need to be in MDI press 1 input to enable. I am working on the initial setup for the machine and am having problems setting the Zero Reference Return position (parameter 1815). 1807 (Series 15), and if needed, FSSB), note the following parameters: [Fl ; Page 31B-65150E/04 2. Feb 3, 2016 · -Move the cursor to “PARAMETER WRITE” . nun bin ich manuell auf die refernzpunkt markierungen gefahren um dann den parameter 1815 in der spalte APC X,Y,Z auf 1 zu Hi I have a Daewoo h63 machine tool with 18 Fanuc control system. When a reference position is set without a dog, (i. I have changed the batteries on both axis. May need to page up or down to get to the top of the Parameter numbers. I would think your procedure would state this. It looks ok now, I may need to twick it a bitMy problem now is the TURRET POSITION. 4 off, then turn 1815. #7 #6 #5 #4 #3 #2 #1 #0 2011 XIAx [Data type] Bit axis #7 IN Specifies whether to enable tentative absolute coordinate system setting, as follows: Jun 24, 2013 · Next, press systems key to get to the parameters screen, scroll to line #1815 and change values from 1 to 0 in both the x and z axis, turn off machine. 3211, bit 4 (NE9) of parameter No. Alarm must power down will appear, DO NOT POWER OFF Nov 16, 2016 · Parameter 1815. To run the machine you must get the parameter list from Fadal. I'm used to being able to set that bit to 1 to set home position, but it's not letting me. 5 = 1 Change Parameter 1815. Grüße aus Gütersloh Holger Sep 22, 2004 · D. Oct 16, 2010 · I've been trying to shift the c-axis 180 degrees. once the grid shift is set, parameter 1815 bit 4 should be made "0" then manual reference return the axis again ( for machines with metric ballscrews the "setting page" should be set "input unit = mm before manual reference return is performed. schau doch bitte mal nach ob in dem Parameter 1815 bei bit 4 und bit 5 (von rechts nach links gelesen und das erste bit ist null) eine 1 hat. If the parameter was a 0 then you would move the axis manually to ref pos and then chenge the 1815 bit 4 to a 1, then you must cycle the power, if you did not do this then this could be where your problem is. parameter 1815 to meet APC value put 0 if 1 4. In this video we will know to how to reference cnc machine by system parameters number 1815,what is the apc,What is the apz,#fanuc ,#siemens ,After watching PARAMETER MANUAL B-64310EN/02 FANUC Series 0+-MODEL D FANUC Series 0+ Mate-MODEL D • No part of this manual may be reproduced in any form. I would assume this will all be verified if I first fire machine and check 1815 bit 4 for XYZ. Thanks in advance for any Jan 1, 2013 · The machine is now telling you it is exceeding the stored stroke limits for each axis. 1005 is set to 1. By BrianM03 in forum Fanuc Replies: 2 Last parameter 1815 has Apc set to 1 and APZ set to 0 when i try to change the zero to 1 it says "write protect" The machine is an Ajax spark X with fanuc series io - mate. HELP!!!! Similar Threads: Problem-417 servo alarm x axis dgtl param; Z Axis Grid Shift Fanuc 0MA; Fanuc 21i lathe, grid shift parameter 1850 issues! Need Help!-Grid Shift C-Axis Mar 22, 2018 · This parameter sets a password for protecting program Nos. PARAMETERS OF THE PRESS FUNCTION 1 1 PARAMETERS OF THE PRESS FUNCTION Address #7 #6 #5 #4 #3 #2 #1 #0 16000 PEI NFI PFI RPF HCI HSP Data type: Bit HSP High–speed press control is: Jan 13, 2008 · OX is correct. Fanuc 3T Parameters; Parameters Fanuc 6M; Last edited by swealf; Turn 1815. So, both bits four and five of parameter 1815 are now set to one. The Controller is a Fanuc 18i-tb, btw. Falls dem so ist geht das einstellen einfacher und schneller. And everything seems fine untill I run a program and then the machine reverts back to the old C zero. 14 (c) Parameters for serial interface spindle amplifier (α series, S series) (1/3) No. The strange part is that it is indicating you are exceeding both the positive and negative limits which would indicate parameter errors (1320, 1321 or 1326, 1327 depending on 1300 bit 2). Caution notices are used where equipment might be damaged if care is not taken. 1815, parameter No. Warnings emphasize that hazardous voltages, currents, temperatures, or other conditions exist in this equipment or may be associated with its use. I've changed parameter 1850. #7 #6 #5 #4 #3 #2 #1 #0 2011 XIAx [Data type] Bit axis #7 IN Specifies whether to enable tentative absolute coordinate system setting, as follows: Aug 27, 2002 · Parameter 3202 bit 4 (reads right to left) enabled (1 is enabled, 0 is disabled) should allow you to edit any 9000 series program on the machine. Views: 235983 . 2. B–63690EN/01 1. Set a proper value in parameter. To call a subroutine on your fanuc control. In normal mode, there is no movement with g01 when the spindle motor stops. Read Download. You first need to make sure that Bit 0 (SQC) of parameter 06005 is set to 1 (See yellow square. The 2 (x12/4000Vis) have absolute pulse coders. Continue with reading or go to download page. Das alle Endschalter auf einmal defekt sind ist zwar unwahrscheinlich aber doch nicht unmöglich. Machine with Pulse coder Change parameter 1815 bit 4 to 0 (APZ) Line up index marks (Located on the side of the head) Turn off power Turn on power and change parameter 1815 bit 4 back to 1 die harte methode wäre wohl über parameter 1815 bit#4 APC (bin mir aber nicht ganz sicher) damit wird der maschinen-nullpunkt verändert. If I go thru power up a couple times I can get it to seat at a legitimate tool. Apr 4, 2015 · fanuc machine--- tape and drill mate model t 1990 fanuc omc control mistake # 1 changed back up batt. 4- Zero your work shifts and 1850 grid shift for x and z. It's first line is for the X axis and the next two lines under it are for the Y and Z axes. 0 means no position held? 3. Thanks! Confirm Parameter 1815. Joined May 8, 2019 Location Parameter 1815 APZ bit Apr 8, 2017 · ok here is the story awea model 4025z/ fanuc 31i b serial 1222212, last week the spindle burned up. Die Maschine hat absolut Encoder, und hat Ihre Standmaße verloren. As whippin boy noted, look at parameter 1815 APZ bits, they should be 1. bit 4 to 0 Check parameter 1320 and 1321 and record the settings Change parameter 1320 to +99999999 and 1321 (Z) only to -99999999 Turn off the power to the machine Turn on the power Using the MPG line up the marks on the Z axis column with the mark on the head Change parameter 1815. This should bring up parameter 1815. 1005 is set to 1) reference position return after reference position setting is performed using rapid traverse at all times, regardless of the setting of SJZ. Changed 1815 bit 5 (APZ) from 0 to 1. Make sure axis position is at your requirment home position for each x and y before doing this 5. 4. When a value other than zero is set in this parameter and this value differs from the keyword set in parameter No. Jun 30, 2015 · 1) Both spindles are of the built in type and do not have a normal Servo Amps driving their C axis positions. Then release P and Cancel keys . Gruß Andy PARAMETER BIT VALUE CHANGE; 1300: 1: 1: Turn off overtravel alarm when handle jogging: 5101: 2: 1: G83 Full Retract: 3202: 0: 1: Lock 8000 Programs: 3202: 4: 1: Lock 9000 Programs Aug 4, 2021 · Type 1815 and press "No. 1815 bit 5 set to “0” will disable an alarm 310 with an Absolute Pulse Page 93. I have done this way too many times recentlylong story. Don't shut anything down, set bit 4 back to a 1, then bit 5 back to a 1. Multiply the machine position X 25400, insert this number in parameter 1241. And he has no manuals for the machine. This may vary on different controls and the newer Fanuc controls will actually place 9000 series programs is a different directory. You don't need to do a grid shift, you need to use a different procedure to reset the axis. Oct 5, 2006 · I have a custom machine with 3 fanuc servos. Thanks MJM Jan 17, 2021 · bei einer Fanuc 18 T Steuerung wurden die Leistungsteile in X und Z von mir getauscht. e. 4 (APZ) auf 0 dann wieder auf 1. Bit 5 still set at 1, bit four at zero. 3202 for protecting program Nos. Set bit #4 to zero (5th position from the right and labeled APZ on the Fanuc 21imB Controller) on all three lines X-Y-Z. 1815 (Series 15, 16, and 18), bit 3 of parameter No. (Do not hold in any other keys or risk loosing parameters, programs and more) Once powered up fully perform Zero May 18, 2006 · DMG/Mori is very helpful over the phone but no-one knows yet why the zero return = Valid/Invalid option under the customize screen does not show up. V axis (magazin) not search zero after the switch on procedure (parameter 1815 bit #5 APCx is 1 (absolute encoder). Spindle orientation parameter list Please see Spindle orientation / adjustment parameters . Press (OPRT) and (>) soft key. Die Maschine hat absolut Encoder, und hat Ihre Standmaße verlo Contribute to rstpeng/CNCKnowledgeBase development by creating an account on GitHub. Parameter change procedure for Fanuc series CNC controls. This parameter sets a password for protecting program Nos. Parameter No. First look in parameter 1240. 3) Hit offset key twice and change Parameter Write Enable from 0 to 1 4) Hit feed hold button to silence the parameter write alarm 5) Hit System Key, should bring you to the parameter page by default 6) Type 1815 and hit the "No. 1815 bit 1 is set for XYZ and no other bits set EXCEPT B axis, which does have bit 4/5 set for absolute. (parameter 1815 bit #5 APCx is 1 (absolute encoder). About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Jun 7, 2016 · set, parameter 1815 bit 4 should be made “0” then manual reference return the axis again ( for machines with metric ballscrews the “setting page” should be set “input unit = mm before manual reference return is performed. ) Dec 6, 2010 · Parameter 1815 bit 5 (APC) determines if you have selected that a particular axis will use battery backup. -Turn on PWE (Parameter Write) make it a 1-Press the function Hard key "SYSTEM"-Press the softkey "PARAM"-Type1815 and press "No. Don't shut anything down, set bit 4 back to a 1, then bit Jan 14, 2006 · However, the turret seats between tool stations, almost like a half index. we needed to run in the spindle so i went to param 1815 /it read 00000010 bit 4 and 5 vanished, so i changed bit 1 to 0 and set bit 4 and 5 to 1. gromznopkhjjdetxztildddajldkzvntahpqlivlfsbiqpvgxpmgddlhtauyzptlwuotcfrbhsygy